Project originated from an unrelated site visit where it was observed seepage from existing filters and identified that the cause of the loss of containment was incorrect selection of the material of construction.
Scope Of Work
Design for the duplex filter vessels to conform with AS1210-2010 Pressure vessels.
- Service: Water
- Design pressure: 1000 kPa
- Design Temperatures: 2 to 60°C
- Material: Duplex stainless steel
Deliverables
- User requirement specification (URS or vessel data sheet).
- 3D CAD model for review in DWFX format.
- Design report.
- Engineering drawings.
How We Managed This
Use of PV Elite Computer Aided Design.
Value Engineering
Project originated from an unrelated site visit where it was observed seepage from existing filters and put forward that the cause of the loss of containment was incorrect selection of the material of construction.
The new MOC filter vessels no longer exhibit containment leaks.