Pump Station Vibration Assessment

Client was operating 7 pumps on the pump station and required an assessment on the pump station supporting structure which was experiencing high level of vibration.

Challenge: Client was operating 7 pumps on the pump station and required an assessment on the pump station supporting structure which was experiencing high level of vibration.

Services: FEA, Fatigue analysis

Solution: Vibration assessment on the pump station supporting structure was performed via the following steps:

  1. Reviewing the natural frequencies of the structure
  2. Applying the known live loads at a range of excitation frequencies
  3. Review of the harmonic response of the system when subjected to these loads
  4. Comparing the response of the existing and the proposed modified structures.

Type of Work:

Mechanical Engineering

Location:

Melbourne, Victoria

Engineering Phase:

Consultancy

Industries:

Infrastructure, Mining and Minerals

Duration:

1 month